Anonymous. (1998). (S. H. Castro, F. Vergara, M. A. Sanchez, & D. of M. E. C. University of Concepcion, Eds.). Effluent treatment in the mining industry. Concepcion: University of Concepcion.
|
Banks, D., Younger, P. L., Arnesen, R. - T., Iversen, E. R., & Banks, S. B. (1997). Mine-water chemistry: The good, the bad and the ugly. Environ. Geol., 32(3), 157–174.
Abstract: Contaminative mine drainage waters have become one of the major hydrogeological and geochemical problems arising from mankind's intrusion into the geosphere. Mine drainage waters in Scandinavia and the United Kingdom are of three main types: (1) saline formation waters; (2) acidic, heavy-metal-containing, sulphate waters derived from pyrite oxidation, and (3) alkaline, hydrogen-sulphide-containing, heavy-metal-poor waters resulting from buffering reactions and/or sulphate reduction. Mine waters are not merely to be perceived as problems, they can be regarded as industrial or drinking water sources and have been used for sewage treatment, tanning and industrial metals extraction. Mine-water problems may be addressed by isolating the contaminant source, by suppressing the reactions releasing contaminants, or by active or passive water treatment. Innovative treatment techniques such as galvanic suppression, application of bactericides, neutralising or reducing agents (pulverised fly ash-based grouts, cattle manure, whey, brewers' yeast) require further research.
|
Bell, A. V., & Nancarrow, D. R. (1974). Salmon and mining in northeastern New Brunswick (a summary of the northeastern New Brunswick mine water quality program). CIM Bull., 67(751), 44–53.
Abstract: It was aimed toward developing solutions to major water quality problems in the base metal mining regions of northeastern New Brunswick and specifically toward insuring that the extremely valuable fishery resources and aquatic environments of the region could be maintained in the face of existing and future base metal mining developments. The program analyzed in detail the fishery resources of the region, their water quality requirements, the mineral resources of the region and the many aspects of mining waste management at each phase of mine development. This paper describes the reasons for the initial concern and the approach adopted toward finding a solution. It briefly summarizes the important findings and recommendations made to support the conclusion that the fishery resource can be maintained and co-exist with current and future base metal mining developments in the region
|
Benner, S. G., Blowes, D. W., & Ptacek, C. J. (1997). A full-scale porous reactive wall for prevention of acid mine drainage. Ground Water Monitoring and Remediation, 17(4), 99–107.
Abstract: The generation and release of acidic drainage containing high concentrations of dissolved metals from decommissioned mine wastes is an environmental problem of international scale. A potential solution to many acid drainage problem is the installation of permeable reactive walls into aquifers affected by drainage water derived from mine waste materials. A permeable reactive wall installed into an aquifer impacted by low-quality mine drainage waters was installed in August 1995 at the Nickel Rim mine site near Sudbury, Ontario. The reactive mixture, containing organic matter, was designed to promote bacterially mediated sulfate reduction and subsequent metal sulfide precipitation. The reactive wall is installed to an average depth of 12 feet (3.6 m) and is 49 feet (15 m) long perpendicular to ground water flow. The wall thickness (flow path length) is 13 feet (4 m). Initial results, collected nine months after installation, indicate that sulfate reduction and metal sulfide precipitation is occurring. Comparing water entering the wall to treated water existing the wall, sulfate concentrations decrease from 2400 to 4600 mg/L to 200 to 3600 mg/L; Fe concentration decrease from 250 to 1300 mg/L to 1.0 to 40 mg/L, pH increases from 5.8 to 7.0; and alkalinity (as CaCO<inf>3</inf>) increases from 0 to 50 mg/L to 600 to 2000 mg/L. The reactive wall has effectively removed the capacity of the ground water to generate acidity on discharge to the surface. Calculations based on comparison to previously run laboratory column experiments indicate that the reactive wall has potential to remain effective for at least 15 years.
|
Brown, M., Barley, B., & Wood, H. (2002). Minewater treatment; technology, application and policy. London: IWA Publishing.
|