Benner, S. G. (1999). Geochemistry of a permeable reactive barrier for metals and acid mine drainage. Environmental Science & Technology, 33(16), 2793–2799.
Abstract: A permeable reactive barrier, designed to remove metals and generate alkalinity by promoting sulfate reduction and metal sulfide precipitation, was installed in August 1995 into an aquifer containing effluent from mine tailings. Passage of groundwater through the barrier results in striking improvement in water quality. Dramatic changes in concentrations of SO4 (decrease of 2000-3000 mg/L), Fe (decrease of 270-1300 mg/L), trace metals (e.g., Ni decreases 30 mg/L), and alkalinity (increase of (800-2700 mg/L) are observed. Populations of sulfate reducing bacteria are 10 000 times greater, and bacterial activity, as measured by dehydrogenase activity, is 10 rimes higher within the barrier compared to the up-gradient aquifer. Dissolved sulfide concentrations increase by 0.2-120 mg/ L, and the isotope S-34 is enriched relative to S-32 in the dissolved phase SO42- within the barrier. Water chemistry, coupled with geochemical speciation modeling, indicates the pore water in the barrier becomes supersaturated with respect to amorphous Fe sulfide. Solid phase analysis of the reactive mixture indicates the accumulation of Fe monosulfide precipitates. Shifts in the saturation states of carbonate, sulfate, and sulfide minerals and most of the observed changes in water chemistry in the barrier and down-gradient aquifer can be attributed, either directly or indirectly, to bacterially mediated sulfate reduction.
|
Berg, G. J., & Arthur, B. (1999). Proposed mine water treatment in Wisconsin. In D. Goldsack, N. Belzile, P. Yearwood, & G. J. Hall (Eds.), Sudbury '99; mining and the environment II; Conference proceedings. Sudbury: Sudbury Environmental.
Abstract: Water quality standards are driving wastewater effluent limits to ultra-low levels in the nanogram/L range. Standards are proposed that require discharges to match background water quality. The new ultra-low level standards require cautious sampling techniques, super clean laboratory methods and more advanced treatment technologies. This paper follows a case history through water quality standards for ultra-low metals, laboratory selection, and the design of a wastewater treatment system that can meet the water quality standards which are required to permit a proposed copper and zinc mine in Northern Wisconsin. A high degree of care must be taken when sampling for ultra-low level metals. Both surface water and treated effluent samples present new challenges. Sampling methods used must assure that there are no unwanted contaminants being introduced to the samples. The selection of a laboratory is as critical as the construction of a state of the art wastewater treatment system. Treatment methods such as lime and sulfide precipitation have had a high degree of success, but they do have limitations. Given today's ultra-low standards, it is necessary to assess the ability of reverse osmosis, deionization, and evaporation to provide the high level of treatment required.
|
Berthelot, D., Haggis, M., Payne, R., McClarty, D., & Courtain, M. (1999). Application of water covers, remote monitoring and data management systems to environmental management at uranium tailings sites in the Serpent River Watershed. CIM Bull., 92(1033), 70–77.
Abstract: Over forty years of uranium mining in the Elliot lake region of Ontario (1956-1996) has resulted in the production of over 300 million pounds of uranium. With the completion of mining activity Rio Algom limited and Denison Mines limited are utilizing progressive environmental technologies and management systems to reduce and manage the environmental risks associated with the 150 million tonnes of potentially acid-generating tailings in nine regional waste management areas. Water covers designed to reduce oxygen entry and, thereby, significantly inhibit acid generation, have been applied at six of the sites with the Quirke site serving as a demonstration site for the Mine Environmental Neutral Drainage program, All five of Rio Algom limited's effluent treatment plants are monitored and controlled from a central control station utilizing a Supervisory Control and Data Acquisition (SCADA) system based on “Fix Dmacs” technology Scheduling, auditing and reporting of plant operating and environmental monitoring programs for the entire watershed are controlled utilizing the Regional Environmental Information Management System (REIMS). Proper application of these technologies and management systems facilitates delivery of cost-effective environmental monitoring, care and maintenance programs at these sites and provides tools to demonstrate compliance with all environmental performance criteria.
|
Bertrand, S. (1997). Performance of a nanofiltration plant on hard and highly sulphated water during two years of operation. Desalination, 113(2-3), 277–281.
Abstract: A highly sulphated, hard water from a flooded iron mine was treated by nanofiltration for the production of drinking water (125 m(3)/h). This paper introduces the context and summarizes the configuration and operating conditions of the plant. The process performance in terms of product water quality and permeability during the first 2 years is presented and discussed.
|
Bhole, A. G. (1994). Acid-Mine Drainage And Its Treatment. Impact of Mining on the Environment, , 131–141.
|