Kim, A. G. (1982). Acid mine drainage: control and abatement research. United States / Bureau of Mines: Information circular. 1925 -, , 22.
|
|
|
Baskin, L. (1979). Linear relationship between mine flow-acid load and influence of depositional environment. In Underground coal mining symposium. New York City: McGraw-Hill.
|
|
|
Laine, D. M., & Jarvis, A. P. (2003). Design aspects of passive in situ remediation schemes for minign & industrial effluents. Tübinger Geowissenschaftliche Arbeiten, C68, 95–113.
|
|
|
Carlson, L., & Kumpulainen, S. (2001). Retention of harmful elements by ochreous precipitates of iron. Tutkimusraportti Geologian Tutkimuskeskus, -(154), 30–33.
Abstract: The capability of soil fines to fix harmful elements, e.g. heavy metals and arsenic, depends on specific surface area and other characteristics, such as surface charge. In the pH-range typical of natural waters (pH 5,5-7,5), the surfaces of fine-grained silicate particles and manganese oxides are negatively charged; consequently cations, such as heavy metals, fix effectively to them. The iron oxide surfaces are usually positively charged and typically fix anions, such as sulphate and arsenate. Retention of anions is especially extensive to precipitates formed from acid mine drainage (pH 2,5-5,0). For example, precipitates found at Paroistenjarvi mine, Finland, contain more than 70 g/kg of arsenic (dry matter). Adsorbed anions, e.g. sulphate, enhance the capacity of precipitate to fix heavy metal cations in low-pH environments.
|
|
|
Younger, P. L. (2000). Holistic remedial strategies for short- and long-term water pollution from abandoned mines. Transactions of the Institution of Mining and Metallurgy Section a-Mining Technology, 109, A210–A218.
Abstract: Where mining proceeds below the water-table-as it has extensively in Britain and elsewhere-water ingress is not only a hindrance during mineral extraction but also a potential liability after abandonment. This is because the cessation of dewatering that commonly follows mine closure leads to a rise in the water-table and associated, often rapid, changes in the chemical regime of the subsurface. Studies over the past two decades have provided insights into the nature and time-scales of these changes and provide a basis for rational planning of mine-water management during and after mine abandonment. The same insights into mine-water chemistry provide hints for the efficient remediation of pollution (typically due to Fe, Mn and Al and, in some cases, Zn, Cd, Pb and other metals). Intensive treatment (by chemical dosing with enhanced sedimentation or alternative processes, such as sulphidization or reverse osmosis) is often necessary only during the first few years following complete flooding of mine voids. Passive treatment (by the use of gravity-flow geochemical reactors and wetlands) may be both more cost-effective and ecologically more responsible in the long term. By the end of 1999 a total of 28 passive systems had been installed at United Kingdom mine sites, including examples of system types currently unique to the United Kingdom. Early performance data for all the systems are summarized and shown to demonstrate the efficacy of passive treatment when appropriately applied.
|
|